Install AAHC

Installation

triangle-exclamation

To install and get started using Applied Analytics, you need to:

  1. Upload a New SSL Certificate to Connect with Logpoint.

  2. To convert timestamp values into your preferred date format, install the Format Date command

  3. To display up to 10,000 logs from the search results, install the Randomize command.

  4. Install AAHC.

    1. You can customize storage partitions during installation.

You can also install and administer Applied Analytics using the command line.

chevron-rightCheck System Requirementshashtag

Component
Requirement

Number of CPU

Minimum 2 CPU cores

RAM

Minimum 1 GB

HDD

Minimum 50 GB

chevron-rightUpload a New SSL Certificatehashtag

Logpoint recommends uploading a new SSL certificate to the Logpoint server instead of using the default SSL certificate that comes with the ISO. The format of the certificate must be in Privacy-enhanced Mail (PEM).

If you are using a multi-level SSL certificate, upload the full certificate chain onto AAHC for secure communication.

  1. Go to Settings >> System Settings from the navigation bar and click System Settings.

  2. Click HTTPS from the left navigation bar.

  3. Browse and upload the certificate and the key.

  4. Click Save.

chevron-rightVersions and Dependencieshashtag

Version

Dependency

Supported On

AAHC v1.1.0

AAHC v1.0.0

Logpoint v5.6.4 and later

AAHC v1.1.1

AAHC v1.1.0

Logpoint v5.6.4 to v6.0.1

AAHC v1.2.0

AAHC v1.1.1

Logpoint v5.6.4 and later

AAHC v1.3.0

AAHC v1.2.0

Logpoint v5.6.4 and later

AAHC v1.3.0-Demo

AAHC v1.3.0

Logpoint v5.6.4 and later

AAHC v1.4.0

AAHC v1.3.0 or AAHC v1.3.0-Demo

Logpoint v6.4.0 and later

AAHC v1.4.1

AAHC v1.4.0

Logpoint v6.4.0 and later

AAHC v1.5.1

AAHC v1.4.0 or AAHC v1.4.1

Logpoint v6.4.0 and later

AAHC v1.5.2

AAHC v1.5.1

Logpoint v6.4.0 and later

AAHC v1.6.0

AAHC v1.5.2, AAHC v1.5.1

Logpoint v6.4.0 and later

AAHC v1.6.1

AAHC v1.6.0

Logpoint v6.4.0 and later

AAHC v1.7.0

AAHC v1.6.0 or AAHC v1.6.1

Logpoint v6.4.0 and later

AAHC v1.7.1

AAHC v1.7.0

Logpoint v6.4.0 and later

AAHC v1.8.0

AAHC v1.7.1

Logpoint v6.4.0 and later

AAHC v1.8.1

AAHC v1.8.0

Logpoint v6.4.0 and later

AAHC v1.9.0

AAHC v1.8.0 or AAHC v1.8.1

Logpoint v6.4.0 and later

AAHC v1.10.1

AAHC v1.9.0

Logpoint v6.4.0 and later

AAHC v1.11.0

AAHC v1.10.1

Logpoint v7.2.0 and later

chevron-rightUpdating Logpointhashtag

We recommend you update AAHCarrow-up-right to its latest version.

  1. Download the Logpoint .pak file from the Help Centerarrow-up-right.

  2. Log into the remote Logpoint server.

  3. Go to Settings >> System Settings from the navigation bar and click Application.

  4. Select Import and Upload the downloaded .pak file.

chevron-rightInstall the Format Date Process Commandhashtag

Install Format Date Process Command to convert timestamp values into your preferred date format. You can specify the exact format in which you want the timestamp to be converted.

  1. Download the Format Date Process Plugin .pak file from the Help Centerarrow-up-right.

  2. Log into the remote Logpoint server.

  3. Go to Settings >> System Settings from the navigation bar and click Application.

  4. Select Import and Upload the earlier downloaded .pak file.

chevron-rightInstall the Randomize Process Commandhashtag

Install Randomize Process Command to display up to 10,000 random logs from the search results.

  1. Download the Randomize .pak file from the Help Centerarrow-up-right.

  2. Log into the remote Logpoint server.

  3. Go to Settings >> System Settings from the navigation bar and click Application.

  4. Select Import and Upload the earlier downloaded pak file.

chevron-rightDownload latest AAHC ISO filehashtag
  1. Go to Applied Analyticsarrow-up-right in the Logpoint Help Center.

  2. Enter your credentials and log in.

  3. Click Applied Analytics For Healthcare v1.8.0 ISO.

  4. Download the ZIP file from Download.

  5. Extract the ZIP file.

chevron-rightInstalling AAHC v1.8.0 ISOhashtag
  1. Power on the Logpoint instance or server that has the ISO file.

  2. On Network connections, you can manually configure the network interfaces or proceed with the default configurations. By default, AAHC uses the IPv4 protocol with Automatic (DHCP) configurations for the first network interface.

    1. If you have multiple network interfaces, you must manually enable and configure each successive interface.

    2. To learn how to configure network interfaces, go to Configuring network interfaces.

  3. Click Done.

  4. The AAHC ISO automatically partitions your storage devices for the installation using the following sizes:

Partition

Mount Point

Size

boot

/boot

1GB

swap

8GB

The remaining space is used for the following volumes:

Volume

Mount Point

Size

root

/

20GB

application

/opt

20%

storage

/opt/aahc/storage

All remaining space

  1. You can manually customize storage devices by selecting Reset. To learn more, go to Customize storage partitions.

  2. Select Done.

  3. Select Continue to start the installation process.

  1. Select Reboot Now. 8.1. The system reboots once more to complete the installation. 8.2. If the installation process fails, you must erase all the data on the disk before reinstalling AAHC.

  2. After the installation completes, you must either manually eject the boot disk or select the option to boot from the hard drive from the Boot Manager. If you don't, the entire process will repeat.

Login to the installed system:

  1. Change the password immediately using the passwd command.

  2. The README.txt file in the home directory of the web-admin user gives you an overview of the actions that can be carried out.

  3. Use the ifconfig command to view the IP address of the installed AAHC machine.

  4. Enter the IP address in your browser to access the AAHC Interface. Log in with:

  1. Change the password immediately.

chevron-rightConfiguring Network Interfaceshashtag
  1. To configure a network interface, select it.

  1. Select Edit IPv4.

  2. Select a Method:

    1. If you select Automatic (DHCP), the network interface settings are automatically set.

    2. If you select Manual, enter a Subnet, Address, Gateway, Name servers, and Search domains.

  3. Select Save.

chevron-rightCustomizing Storage Partitions During Installationhashtag
  1. In Storage Configuration, select Reset.

  1. Select Use As Boot Device for the device to boot AAHC on.

  1. Select Add GPT Partition for an available device.

  1. Enter Size. The recommended size is at least 8GB for a new partition.

  1. Select swap in Format and select Create.

  2. Select Add GPT Partition again for the remaining size.

  3. Select Leave unformatted in Format and select Create. This unformatted partition can be used to hold the logical volume group.

  1. Select Create Volume Group (LVM) to create a new volume group.

circle-info

You can also create software RAID (md) disks.

  1. Enter a name for the volume group and select Create.

  1. In the new volume group, select Create Logical Volume.

  1. Enter a Name, Size, Format, and Mount point for the new logical volume.

  1. You must configure at least the following logical volumes before you can proceed with the installation:

Name

Mount point

Minimum size

boot

/boot

1GB

root

/

20GB

application

/opt

20%

storage

/opt/aahc/storage

60GB

circle-info

The installer automatically provides the names and mount points for the next default volume group every time you select Create Logical Volume.

  1. Select Done after finalizing your storage configurations.

AAHC Release Cycle

Released ISOs

Released Patches

1.8.0

1.8.1, 1.9.0, 1.10.1, 1.11.0

1.0.0

1.1.0, 1.1.1, 1.2.0, 1.3.0, 1.4.0, 1.4.1, 1.5.0, 1.5.1, 1.5.2, 1.6.0, 1.6.1, 1.7.0, 1.7.1, 1.8.0, 1.8.1, 1.9.0, 1.10.1, 1.11.0

chevron-rightUpgrade AAHC Patchhashtag

Before upgrading to a new version, ensure Logpoint is configured in AAHC.

  1. Go to Applied Analyticsarrow-up-right in the Logpoint Help Center.

  2. Click the AAHC patch that you want to install.

circle-info

Make sure the patch you are installing is compatible with your AAHC's current version. Go to Versions and Dependencies.

  1. Download the ZIP file from the Download section.

  2. Extract the ZIP file to obtain the .pak file.

  3. Copy the .pak file to the /home/web-admin directory of the AAHC server.

  4. Run the following command to install the patch:

circle-info
  • AAHC automatically reboots after installing a new patch.

  • You must log in again after installing the patches.

  • AAHC prompts you to change your password after upgrading to a new patch.

Last updated

Was this helpful?